THERMOCOUPLE
|
- Type : W, B, R, S, N, K, E, J, T
- Class of Thermocouple : Class 1 and Class 2
- Variation material protection tube : (SS316,Hasteloy,Inconel,and so on) Metallic and ( Recrystallized alumina,Mulite,Silimanite, and so on ) Non-Metallic
- Duplex or single pairs
- Flange rating : JIS, ANSI, DIN
- Hazardous area : Flame Proof Head
Approved by KEMA:
No. KEMA 03A TEX2002 X, II2G EEx de IIC T6...T1 (for Temperature Sensors)
No. KEMA 03A TEX2003, II2G EEx d IIC T6 (for Temperature Transmitters and Terminal Enclosure)
To: EN 50014:1997, General requirements
EN 50018:2000, Flameproof enclosure "d"
EN 50019:2000, Increased safety "e" (for Temperature Sensors)
Approved by Research Institute of Industrial Safety, Ministry of Labor, Japan (R.I.I.S):
Exd IIC T6
|
| Top |
|
|
|
|
RTD
|
- Type : PT100,JPT100,PT50
- Class of RTD : Class A and Class B
- 2-wires, 3-wires,or 4-wires
- Variation material protection tube : (SS316,Hasteloy,Inconel,and so on) Metallic and (Recrystallized alumina,Mulite,Silimanite, and so on) Non-Metallic
- Hazardous area : Flame Proof Head
- Flange rating : JIS, ANSI, DIN
Approved by KEMA:
No. KEMA 03A TEX2002 X, II2G EEx de IIC T6...T1 (for Temperature Sensors)
No. KEMA 03A TEX2003, II2G EEx d IIC T6 (for Temperature Transmitters and Terminal Enclosure)
To: EN 50014:1997, General requirements
EN 50018:2000, Flameproof enclosure "d"
EN 50019:2000, Increased safety "e" (for Temperature Sensors) Approved by Research Institute of Industrial Safety, Ministry of Labor, Japan (R.I.I.S):
Exd IIC T6
|
| Top |
|
|
|
|
THERMOWELL
|
Material’s Variation :
- Stainless Steel* 304, 321, 316, 347, 310, 446, 253MA, Inconel 600, 601, 625, X-750, Incoloy 800, 825, Hastelloy B, C276, X Others Haynes 25, Carpenter 20Cb, Nichrome, HCF, 50Co-30Cr, Monel, Brass, Bronze, Titanium, Tantalum, Molybdenum *Low carbon types of Austenite S.S. are available on request.
- Ceramic : Translucent Quart / Transparent Quart (QT), Silimanite (PT2), Mullite (T1), Recrystallized Alumina (PT0), LT1, 2040, ZR 1706, etc.
Test and Inspection :
- Pressure Test
N2 gass pressure test up to 10MPa is conducted upon request.
- Hydrostatic Pressure Test
Internal pressure test up to 40MPa is conducted upon request.
- X-Ray Inspection
X-ray inspection to insure uniform wall thickness or complete finish is also performed upon request.
Flange rating : JIS (RF & FF), ANSI (RF & RTJ), DIN
|
| Top |
|
|
|
|
EXTENTION WIRES
|
- Many type thermocouple wires : W, B, R, S, N, K, E, J, T
- International color standars colors code : JIS, ASTM, BS, DIN, NF, IEC 584-3
- Many kinds material of insulation cable : PVC Sheath, Glass Fiber Sheath, Silicon Rubber Sheath, Teflon, And Metal Sheath.
|
| Top |
|
|
|
|
|
|
|
|
|